Product Details:
Brand | EST |
Mounting | Two local rail spaces on top of 3-CPU |
Common Control Switches and LEDs | Reset switch and LED Alarm Silence switch and LED Panel Silence switch and LED Drill Switch and LED |
Alarm Current | 42mA |
Standby Current | 40mA |
Catalog Number | 3-LCD |
Agency Listings | UL, ULC, FM, CE, LPCB EN54* pending |
LCD Display | Eight lines by 21 characters backlit LCD |
Product Details:
Brand | EST |
Usage/Application | Provides interface for one Control Display Module |
Model Name/Number | 3-LDSM |
Alarm Current | 5 mA |
Shipping Weight | 0.45lb (.2kg) |
Country of Origin | Made in India |
Product Details:
Material | Mild Steel |
Brand | EST |
Series | 3-CAB Series |
Equipment Mounting Space | Five local rail modules One footprint and 1/2 footprint module |
Battery Space | Two - 12V10A |
Ship Wt. lb. (Kg) | 30 (13.6) |
Product Details:
Agency Listings | UL, ULC, CE |
Ambient Temp. | 0 Degree C-49 Degree C (32 Degree F-120 Degree F) |
Bilingual Support | English, Dutch, Finnish, French, German, Italian, Portuguese, Spanish |
Mounting | One Chassis Space |
Supported Message Count | 255 |
Auxiliary Input impedance | 1K Ohm |
Series | 3-ASU Series |
Brand | EST |
Ambient Humidity | 93% Non-condensing @ 32 Degree C |
Product Details:
Brand | Edwards |
Modules Supported | 125 Module Addresses per 3-SDC1 Card |
2-Wire Smoke Power Output | 100 mA per 3-SDC1 Card (not included in Operating Current above |
Signature Circuit Voltage | 20 VDC +/- 5% |
Maximum Signature Circuit Capacitance | 0.33 uF |
Catalog Number | 3-SSDC1 |
Module Configuration | 1 Addressable circuit (3-SDC1 Card) expandable to 2 circuits. |
Operating Current | Standby 144 mA Alarm 204 mA |
Operating Voltage | 24 Vdc, Nominal |
Address Requirements | Automatic |
Detectors Supported | 125 per 3-SDC1 Card |
Maximum Signature Circuit Resistance | 100 Ohms |
Product Details:
Output Voltage | 24V |
Input Voltage | 120 Vac (+10%, -15%), 50-60 Hz |
Input Current | 3.0 A |
Auxiliary Output Terminal Capacity | 18 AWG to 12 AWG (1 mm2 to 2.5 mm2) |
Agency Approvals | UL, ULC |
Ground Fault Detection | < 10K Ohms |
Brownout Level | < or = 102 Vac |
Total Output Current | Special Applications: 7.0 Amps |
Product Details:
Model Name/Number | 3-ZA20A |
Environmental | 0 Degree C - 49 Degree C (32 Degree F - 120 Degree F) 93% RH, Non-condensing |
Agency Listing | UL, ULC, CE |
Internal Tone Generator | 1KHz Temporal (3-3-3) Tone (evacuation); 20 PPM (alert) |
Frequency Response | 400Hz to 4KHz @ +/- 3dB |
Output Voltage | 25 VRMS or 70 VRMS |
THD (distortion) | < 7% |
Alarm Current | 1120mA |
SIGA-CC1/2 Support | 10 Units, Maximum |
Wire Size | 18 to 12 AWG (1.0 to 2.5 mm2) |
Product Details:
Mounting | 2 - Left most local rail spaces |
Terminal Size | 18-12 AWG (1.0mm2 to 2.5mm2) |
Alarm Current | 155 mA |
Agency Listings | UL, ULC, CSFM, CE, LPCB EN54* pending. |
Data Down Loading | RJ45 Jack |
Operating Environment | 0 Degree C - 49 Degree C (32 Degree F - 120 Degree F); 93% at 40 Degree C Non-Condensing |
Contact Ratings | Nonbypassable Alarm, Supervisory and Trouble Form 'C' 1A at 30 Vdc |
Standby Current | 145 mA |